sisHYD User Guide

Options Tab

The defaults for logs and functions are set in the tab "options".
  • Logging – In this group, the settings for logging for network calculation are made.
  • Fatal – Serious errors which lead to the abortion of network calculation. This kind of error is always logged.
  • Error – Error during network calculation (e.g., exceeding/falling below limit values, errors in configuration data). This kind of error is always logged.
  • Warning – Warnings about possible errors (e.g., warnings about nodes with only one attached pipe).
  • Information – Most important information on the execution of network calculation (e.g., number of iteration steps with hydraulic calculation, display of the most important indexing steps during network calculation).
  • Topology – Messages about dead "branches" and "dead ends" in the network are given if this field is marked.
  • Function – Activated tasks for the calculation can be switched on and off using the option switches.
  • Update Drawings – If this field is marked, then sisHYD automatically creates a set of network sketches with the new calculation result.
    • Network sketches are always based on a design template. sisHYD determines the created network sketches and associated templates from the latest result. The new results are applied to the templates thus found.
  • Start Design Result Wizard – Starts the assistant to update the pipes pipe classes with the results of the dimensioning, after a successful design calculation.